Span Tables for Case 1:
Maximum Building Height = 4.8m Single Span
- No Overhang
150 x 50mm ALYSPAN Beam
Maximum Building Height = 4.8m Single Span
- No Overhang
100 x 50mm ALYSPAN Beam
Single Span - No Overhang
Max. Adjacent Building Height = 4.8m
W | Maximum Allowable Span (mm) | ||||
N1 | N2 | N3 | N4 | N5 | |
1500 | 3700 | 3700 | 3100 | 2600 | 2200 |
1800 | 3500 | 3500 | 2900 | 2400 | 2100 |
2100 | 3300 | 3300 | 2700 | 2300 | 1900 |
2400 | 3200 | 3200 | 2600 | 2200 | 1800 |
2700 | 3000 | 3000 | 2500 | 2100 | 1700 |
3000 | 2900 | 2900 | 2400 | 2000 | 1600 |
3300 | 2800 | 2800 | 2300 | 1900 | 1500 |
3600 | 2700 | 2700 | 2300 | 1800 | 1400 |
3900 | 2700 | 2700 | 2200 | 1700 | 1300 |
4200 | 2600 | 2600 | 2100 | 1600 | 1300 |
4500 | 2500 | 2500 | 200 | 1500 | 1200 |
Single Span - No Overhang
Max. Adjacent Building Height = 4.8m
W | Maximum Allowable Span (mm) | ||||
N1 | N2 | N3 | N4 | N5 | |
1500 | 5100 | 5100 | 4200 | 3600 | 3100 |
2000 | 4700 | 4700 | 3800 | 3300 | 2600 |
2500 | 4300 | 4300 | 3600 | 2900 | 2300 |
3000 | 4100 | 4100 | 3300 | 2600 | 2100 |
3500 | 3900 | 3900 | 3100 | 2400 | 1900 |
4000 | 3700 | 3700 | 2900 | 2300 | 1800 |
4500 | 3500 | 3500 | 2700 | 2100 | 1700 |
5000 | 3400 | 3300 | 2500 | 2000 | 1600 |
5500 | 3300 | 3100 | 2400 | 1900 | 1500 |
6000 | 3200 | 3000 | 2300 | 1800 | 1400 |
6500 | 3100 | 2900 | 2200 | 1700 | 1300 |
7000 | 3000 | 2800 | 2100 | 1600 | 1300 |